RS PRO IM-502 Air Quality Monitor for CO2, Humidity, Temperature, +122 °F, +50 °C Max, 95%RH Max, Mains-Powered
Technical Document
Specifications
Brand
RS ProMaximum Temperature
+122 °F, +50 °C
Best Temperature Measurement Accuracy
±1.0 °C, ±1.8 °F
Power Source
Mains
Equipment Type
Air Quality Monitor
Temperature Measurement Resolution
0.1 °C, 0.1 °F
Maximum Humidity Measurement
95%RH
Best Humidity Measurement Accuracy
±3 %
Humidity Measurement Resolution
0.1%
Measurement Parameters
CO2, Humidity, Temperature
Best Carbon Dioxide Accuracy
±5%
Carbon Dioxide Resolution
±1ppm
Model Number p
IM-502
Width
62mm
Length
89mm
Minimum Carbon Dioxide Level
0ppm
Maximum Carbon Dioxide Level
9999ppm
Height
128mm
Weight
190g
Display Type
LCD
Country of Origin
Taiwan, Province Of China
Product details
RS PRO Desktop Indoor Air Quality Meter IM-502 CO2
This RS PRO desktop indoor air quality (IAQ) meter can measure Carbon Dioxide, ventilation rate, temperature and humidity. This meter ensures long-term stability and durability making this a great device for indoor air quality measurement and monitoring.
Features and Benefits
- Non-Dispersive Infrared (NDIR) CO2 sensor ensures long-term stability and durability
- 4 Measurements in one monitor, CO2, CO2 Ventilation Rate, Temperature and Humidity
- Large display for easy viewing
- Easy-to-use PC software for parameter settings and analysis
- Fast USB download
- Internal memory stores up to 17000 data
- Selectable record time Interval
- CO2/Temperature/Humidity high, low alarm setting
- Set on the table or wall-mounted (with1/4" tripod nut)
- Maximum/Minimum values
Typical Applications
Generally, air quality monitors locate and monitor a variety of gases, dust, fumes and particles that could be dangerous and harmful to the breathable air quality for humans. Air quality meters work to measure and monitor the air quality to ensure that it is safe enough and acceptable enough to work or live in. Often, air quality meters can be used in environments like:
- Offices
- Building HVAC monitoring
- Indoor air quality survey
FAQs
What does it measure?
Carbon Dioxide
- Measurement Range: 0 to 9999ppm
- Accuracy: ±5% read value or ±75ppm(0-2000ppm)
- Resolution; ±1ppm
- Response Time: Reaches 90% in approximately 2 minutes
Temperature
- Measurement Range: 0°C∼50°C / 32°F∼122°F
- Accuracy: ±1.0°C/±1.8°F
- Resolution: 0.1°C/0.1°F
- Response Time: Approximately 1 second
Relative Humidity
- Measurement Range: 5-95%
- Accuracy; ±3.0%RH (20∼80%); ±5.0%RH(<20%,>80%)
- Resolution: 0.1%
- Response Time: Approximately 4 seconds
Why choose RS PRO?
RS PRO is our own brand of high-quality products whilst bringing you great value for money. Our wide range of products have been engineered to meet high industry standards, so you are ensured reliable and robust solutions.
Stock information temporarily unavailable.
Please check again later.
€ 336.58
Each (ex VAT)
1
€ 336.58
Each (ex VAT)
1
Technical Document
Specifications
Brand
RS ProMaximum Temperature
+122 °F, +50 °C
Best Temperature Measurement Accuracy
±1.0 °C, ±1.8 °F
Power Source
Mains
Equipment Type
Air Quality Monitor
Temperature Measurement Resolution
0.1 °C, 0.1 °F
Maximum Humidity Measurement
95%RH
Best Humidity Measurement Accuracy
±3 %
Humidity Measurement Resolution
0.1%
Measurement Parameters
CO2, Humidity, Temperature
Best Carbon Dioxide Accuracy
±5%
Carbon Dioxide Resolution
±1ppm
Model Number p
IM-502
Width
62mm
Length
89mm
Minimum Carbon Dioxide Level
0ppm
Maximum Carbon Dioxide Level
9999ppm
Height
128mm
Weight
190g
Display Type
LCD
Country of Origin
Taiwan, Province Of China
Product details
RS PRO Desktop Indoor Air Quality Meter IM-502 CO2
This RS PRO desktop indoor air quality (IAQ) meter can measure Carbon Dioxide, ventilation rate, temperature and humidity. This meter ensures long-term stability and durability making this a great device for indoor air quality measurement and monitoring.
Features and Benefits
- Non-Dispersive Infrared (NDIR) CO2 sensor ensures long-term stability and durability
- 4 Measurements in one monitor, CO2, CO2 Ventilation Rate, Temperature and Humidity
- Large display for easy viewing
- Easy-to-use PC software for parameter settings and analysis
- Fast USB download
- Internal memory stores up to 17000 data
- Selectable record time Interval
- CO2/Temperature/Humidity high, low alarm setting
- Set on the table or wall-mounted (with1/4" tripod nut)
- Maximum/Minimum values
Typical Applications
Generally, air quality monitors locate and monitor a variety of gases, dust, fumes and particles that could be dangerous and harmful to the breathable air quality for humans. Air quality meters work to measure and monitor the air quality to ensure that it is safe enough and acceptable enough to work or live in. Often, air quality meters can be used in environments like:
- Offices
- Building HVAC monitoring
- Indoor air quality survey
FAQs
What does it measure?
Carbon Dioxide
- Measurement Range: 0 to 9999ppm
- Accuracy: ±5% read value or ±75ppm(0-2000ppm)
- Resolution; ±1ppm
- Response Time: Reaches 90% in approximately 2 minutes
Temperature
- Measurement Range: 0°C∼50°C / 32°F∼122°F
- Accuracy: ±1.0°C/±1.8°F
- Resolution: 0.1°C/0.1°F
- Response Time: Approximately 1 second
Relative Humidity
- Measurement Range: 5-95%
- Accuracy; ±3.0%RH (20∼80%); ±5.0%RH(<20%,>80%)
- Resolution: 0.1%
- Response Time: Approximately 4 seconds